EPS15/99: Wiring Diagram



EPS15/99 should not be supported by the electrical conduit. If installed outdoors, water proof connections are needed.

Error Codes

E1= Rapid cycle
Note: E1 will flash if the pump cycles off and on more than 20 times in four minutes. TheE1 display will not clear until the reset button is held for 5 seconds. This error flashes only and will not turn off the pump.

E2= System pressure has been below 10 PSI or above 100 psi for more than 2 minutes.
Note: If during set up, the pressure switch is left at 00 pressure for more than 2 minutes after it has been powered up, error code E2 will display. To reactivate the pressure switch, pres the mode button for 10 seconds or power off and on the system until 00 appears again on the screen. This will clear the pressure switch error display but does not reset any saved “LO” or “HI” settings.

E3= Power source problems
Note: E3 will flash if incorrect voltage is detected. The pump will be shut off after 2 minutes.

E2 or E3 errors will turn off the pump. To reset the switch, hold down the mode button or 10 seconds or power off/on the switch.